Are you looking quote for part WE-3192? The Wems Electronics-manufactured component (CAGE Code: 26543) is documented under NSN 5950-01-076-3961 as Transformer Power. For the fastest quote, please complete our RFQ form with details about WE-3192. We guarantee a response within 15 minutes.
ASAP Components provides the verified WE-3192, classified under INC 32496, FSG 59 Electrical and Electronic Equipment Components, FSC 5950 Coils and Transformers, NIIN 01-076-3961, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5950-01-076-3961 Item PartTypeName: TRANSFORMER,POWER | 5950 | 010763961 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | U | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 42654 | 5 | 2 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.812 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABTB | MOUNTING HOLE DIAMETER | 0.187 INCHES NOMINAL SINGLE GROUP |
| ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
| ACZF | MAXIMUM TRANSFORMER POWER RATING | 291.9 VOLT-AMPERE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 4.750 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 2.500 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 4.000 INCHES MAXIMUM |
| AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 12 SECONDARY SINGLE COMPONENT |
| CRBZ | WINDING OPERATING CURRENT | 1.84 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 173.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 204.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 81.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CRMJ | WINDING POWER RATING | 2.8 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| CRMJ | WINDING POWER RATING | 3.0 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
| CRMJ | WINDING POWER RATING | 31.8 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
| CRMJ | WINDING POWER RATING | 7.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 10.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 19.80 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 19.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 196.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; TWELVE SECONDARY WINDINGS |
| TTQY | TERMINAL TYPE AND QUANTITY | 39 TAB,SOLDER LUG |
| End Use : 20000 | Generators, accessories |
|---|---|
| Schedule B : 8504314065 (NAICS 334416) | Transformers, having a power handling capaci type 40 va or greater but less than 1 kva, nesoi |
| SITC : 77119 | Electric transformers, n.E.S. |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | U - Precious metal content is unknown |
| AAC | J |
|---|---|
| Classification Control | U |
| MGMT_CTL | Q2200x- |
| Quantity per pack | 1 |
| Repariability | This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item. |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | W - Rating variable |
| NMFC: | 063420 - Transformers, noi, or transformer par |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 595 - Transformer, (machinery and parts),(less than 35 feet) |