Quote for 104 235 102 Tyco Electronics Corporation Part with NSN 5925-00-984-9574

Part Number:  104 235 102
NIIN:  9849574
Item Name :  circuit breaker
CAGE Code:  77342
INC Code:  00136
Country:  USA
NCB Code:  00
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  02-14-2026

Are you looking quote for part 104 235 102? The Tyco Electronics Corporation-manufactured component (CAGE Code: 77342) is documented under NSN 5925-00-984-9574 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about 104 235 102. We guarantee a response within 15 minutes.

ASAP Components provides the verified 104 235 102, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 00-984-9574, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for 104 235 102

“*” Required Fields Are Compulsory

NSN Information for Part Number 104 235 102 with NSN 5925-00-984-9574, 5925009849574

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-00-984-9574

Item PartTypeName:

CIRCUIT BREAKER

5925009849574P
CIICHCCESDPMICCriticalityENAC
U
Part NumberISCRNVCRNCCHCCMSDSSADC
104-235-102123

Characteristics Data of NSN 5925-00-984-9574, 5925009849574

MRCCriteriaCharacteristic
AAQLBODY STYLESINGLE POLE TYPE
ABXDBUSHING LENGTH0.220 INCHES MINIMUM AND 0.280 INCHES MAXIMUM
ADAQBODY LENGTH2.189 INCHES MAXIMUM
ADATBODY WIDTH0.750 INCHES MAXIMUM
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.160 INCHES MINIMUM AND 1.220 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.796 INCHES MINIMUM AND 1.828 INCHES MAXIMUM
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2.000 INCHES MAXIMUM
AKPXPOLE QUANTITY1
APNQARC QUENCHING METHODAIR
AXHRMOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE35.0 AMPERES AC AND 35.0 AMPERES DC SINGLE LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS205.0 AC AND 30.0 DC SINGLE LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS3500.0 AC AND 6000.0 DC SINGLE LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
CPRJTRIP RELEASE METHODTHERMAL SINGLE LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0 SINGLE LOCATION
CPRPULTIMATE TRIP TIME PER POLE IN SECONDS3600.000 NOMINAL SINGLE LOCATION
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 PUSH-PULL
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT15.000 MINIMUM AT 200 PCT AND 55.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT
CRCFTRIP RELEASE AMBIENT TEMP RATING25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
CTJSUNPACKAGED UNIT WEIGHT0.250 POUNDS NOMINAL
CWJKCASE MATERIALPLASTIC
FREQFREQUENCY IN HERTZ400.0 SINGLE LOCATION
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY2 TAB W/SCREW

Schedule B & Trade

End Use : 20005 Electric apparatus
Schedule B : 8536200040 (NAICS 335313) Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi
SITC : 77252 Automatic circuit breakers for a voltage not exceeding 1, 000 volts

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC U - Precious metal content is unknown

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LCL: P - 77.5
LTL: P - 77.5
NMFC: 061300 - Circuit breaker/switch noi
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 658 - Electrical appliances, small

ASAP Semiconductor’s Certifications And Memberships