Are you looking quote for part PSF100A3? The Sensor Systems Inc-manufactured component (CAGE Code: 04454) is documented under NSN 5930-00-858-9780 as Switch Pressure. For the fastest quote, please complete our RFQ form with details about PSF100A3. We guarantee a response within 15 minutes.
ASAP Components provides the verified PSF100A3, classified under INC 00206, FSG 59 Electrical and Electronic Equipment Components, FSC 5930 Switches, NIIN 00-858-9780, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5930-00-858-9780 Item PartTypeName: SWITCH,PRESSURE | 5930 | 008589780 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | G | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| M64-104 | C | 9 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 1.750 INCHES NOMINAL |
| ABKV | OUTSIDE DIAMETER | 0.195 INCHES MINIMUM AND 0.205 INCHES MAXIMUM ALL CONNECTIONS |
| ABKW | OVERALL HEIGHT | 0.478 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 1.312 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 1.000 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.125 INCHES NOMINAL |
| AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.719 INCHES NOMINAL |
| AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.719 INCHES NOMINAL |
| AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |
| AXGY | MOUNTING METHOD | BASE AND UNTHREADED HOLE |
| CQGB | CONTACT ACTION STIMULUS | INCREASE |
| CQJB | PROOF PRESSURE | 8.00 POUNDS PER SQUARE INCH GAGE |
| CQYJ | MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY OPEN,DOUBLE MAKE,MOMENTARY ACTION |
| CSCF | TERMINAL TYPE | QUICK DISCONNECT,MALE |
| CTHF | CONTACT LOAD CURRENT RATING | 10.0 MILLIAMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 10.0 MILLIAMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE |
| CTYX | CONTACT STIMULUS RATING | 3.00 ACTUATION POINT NOMINAL INCHES OF WATER |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 30.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SECOND VOLTAGE |
| CTZL | PRESSURE CONNECTOR TYPE | BARBED,UNTHREADED EXTERNAL ALL CONNECTIONS |
| MEDA | MEDIA FOR WHICH DESIGNED | GAS |
| PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS GOLD |
| PRMT | PRECIOUS MATERIAL | GOLD |
| STYL | STYLE DESIGNATOR | RECTANGULAR |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8536509065 (NAICS 335931) | Switches, for a voltage not exceeding 1000 volts, nesoi |
| SITC : 77255 | Switches for electrical apparatus, n.E.S., for voltages not exceeding 1, 000 volts |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | G - Item contains gold. |
| AAC | Z |
|---|---|
| Classification Control | U |
| MGMT_CTL | Sf9eh-n |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | P - 77.5 |
| NMFC: | 061300 - Circuit breaker/switch noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 658 - Electrical appliances, small |