Are you looking quote for part TR-349-A? The Rosemount Aerospace Inc-manufactured component (CAGE Code: 59885) is documented under NSN 6685-01-373-2860 as Transmitter Pressur. For the fastest quote, please complete our RFQ form with details about TR-349-A. We guarantee a response within 15 minutes.
ASAP Components provides the verified TR-349-A, classified under INC 03375, FSG 66 Instruments and Laboratory Equipment, FSC 6685 Pressure Temperature And Humidity Measuring And Controlling Instruments, NIIN 01-373-2860, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| MRC | Criteria | Characteristic |
|---|---|---|
| AXGY | MOUNTING METHOD | FLANGE BASE |
| AFLW | ACTUATION METHOD | DOUBLE DIAPHRAGM AND PRESSURE SENSING ELEMENT |
| ASSC | MECHANICAL CONNECTION SIZE | MS33649-04 AND MS33649-06 |
| ASSD | MECHANICAL CONNECTION TYPE | NIPPLE |
| BHMW | MEASUREMENT RANGE | 0.0 TO 10.0 INCHES OF MERCURY |
| ASKY | ELECTRICAL CONNECTION CONTROLLING AGENCY | MS3112E MILITARY SPEC |
| ASKZ | ELECTRICAL CONNECTION IDENTIFYING NUMBER | MS3112E12-10P |
| FEAT | SPECIAL FEATURES | PROVIDES BOTH STATIC AND IMPACT PPRESSURE OUTPUTS EXPRESSED IN A PERCENTAGE OF FULL SCALE PREFORMANCE;INPUT POWER 28 VDC,OUTPUT 0-10 VDC;BUILT IN SELF-TEST;QUALIFIED TO MIL-STD-810C ENVIROMMENTS AND MIL-STD-461B EMI ENVIRONMENTS;MEAN TIME BETWEEN FAILURES,100,000 HRS;CIRCUIT PRTECTION 1 REVERSED POLARITY,2 SHORT CIRCUIT OF OUTPUT,3 LONG TERM OVERPRESSURE WILL NOT DAMAGE;OPERATING TEMPERATURE -54 DEG C. TO 71 DEG C.;ALTITUDE SEA LEVEL TO 70,000 FT.;ACCELERATION =/-10GS ALL AXES;CRASH SAFETY 30 GS;HERMATICLY SEALED;MATERIAL ALUMINUM,COATED PER MIL-C-5541 |
| ADUM | OVERALL THICKNESS | 3.460 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 3.460 INCHES NOMINAL |
| AGAV | III END ITEM IDENTIFICATION | MC-130-H AIRCRAFT |
| AKSF | CONTACT TYPE | PIN |
| ALCD | III USAGE DESIGN | AIR DATA TRANSDUCER FOR AIR DATA COMPUTER AND DISPLAYS |
| AMSE | VOLTAGE RATING | 15.0 VOLTS NOMINAL INPUT |
| ABHP | OVERALL LENGTH | 6.330 INCHES NOMINAL |
| AFRA | CONTACT QUANTITY | 10 |
| ASSB | MECHANICAL CONNECTION QUANTITY | 2 |
| ASKX | ELECTRICAL CONNECTION QUANTITY | 1 |
| ACDC | CURRENT TYPE | DC |
| ACUP | MOUNTING DEVICE QUANTITY | 4 |
| End Use : 21160 | Measuring, testing, control instruments |
|---|---|
| Schedule B : 9026800000 (NAICS 334513) | Instruments and apparatus for measuring or checking other variables of liquids or gases, nesoi |
| SITC : 87437 | Instruments and apparatus for measuring or checking the variables of liquids or gases, n.E.S. (not supply etc. Meters and regulating etc. Apparatus) |
| ADPE | Represents items with no adp components |
|---|---|
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| ESD | A - No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity. |
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | C |
|---|---|
| Classification Control | U |
| MGMT_CTL | Sf8lg-n |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Flz |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LCL: | U - 50.0 |
| LTL: | F - 150.0 |
| NMFC: | 058240 - Recording devices gauges/meters noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 72E - Engineer and material handling equipment, test/tool sets and equipment |