| MRC | Criteria | Characteristic |
|---|
| AAQL | BODY STYLE | W/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES" |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
| ABJT | TERMINAL LENGTH | 0.750 INCHES MINIMUM" |
| ADAQ | BODY LENGTH | 0.250 INCHES MINIMUM AND 0.660 INCHES MAXIMUM" |
| ADAT | BODY WIDTH | 0.225 INCHES MINIMUM AND 0.310 INCHES MAXIMUM" |
| ADAU | BODY HEIGHT | 0.110 INCHES MINIMUM AND 0.260 INCHES MAXIMUM" |
| AEBT | TERMINAL DIAMETER | 0.034 INCHES MAXIMUM" |
| AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S)" |
| CQBQ | CAPACITANCE VALUE PER SECTION | 180.000 PICOFARADS SINGLE SECTION" |
| CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM" |
| CQLZ | TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | 90.0 SINGLE SECTION" |
| CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 500.0 DC SINGLE SECTION" |
| CRTP | TOLERANCE RANGE PER SECTION | -5.00/+5.00 PERCENT SINGLE SECTION" |
| CWJK | CASE MATERIAL | CERAMIC" |
| CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS" |
| CWQF | QUALITY FACTOR AT REFERENCE TEMP | 1000.000" |
| FEAT | SPECIAL FEATURES | LEADS ARE AXIAL COPPER WIRE OR SOLID SILVER WIRE" |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD" |
| AAQL | BODY STYLE | W/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES" |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
| ABJT | TERMINAL LENGTH | 0.750 INCHES MINIMUM" |
| ADAQ | BODY LENGTH | 0.250 INCHES MINIMUM AND 0.660 INCHES MAXIMUM" |
| ADAT | BODY WIDTH | 0.225 INCHES MINIMUM AND 0.310 INCHES MAXIMUM" |
| ADAU | BODY HEIGHT | 0.110 INCHES MINIMUM AND 0.260 INCHES MAXIMUM" |
| AEBT | TERMINAL DIAMETER | 0.034 INCHES MAXIMUM" |
| AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S)" |
| CQBQ | CAPACITANCE VALUE PER SECTION | 180.000 PICOFARADS SINGLE SECTION" |
| CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM" |
| CQLZ | TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | 90.0 SINGLE SECTION" |
| CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 500.0 DC SINGLE SECTION" |
| CRTP | TOLERANCE RANGE PER SECTION | -5.00/+5.00 PERCENT SINGLE SECTION" |
| CWJK | CASE MATERIAL | CERAMIC" |
| CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS" |
| CWQF | QUALITY FACTOR AT REFERENCE TEMP | 1000.000" |
| FEAT | SPECIAL FEATURES | LEADS ARE AXIAL COPPER WIRE OR SOLID SILVER WIRE" |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD" |