Are you looking quote for part PR0002-A? The Metermaster Inc-manufactured component (CAGE Code: 25497) is documented under NSN 6625-01-031-0584 as Shunt Instrument. For the fastest quote, please complete our RFQ form with details about PR0002-A. We guarantee a response within 15 minutes.
ASAP Components provides the verified PR0002-A, classified under INC 00122, FSG 66 Instruments and Laboratory Equipment, FSC 6625 Electrical And Electronic Properties Measuring And Testing Instruments, NIIN 01-031-0584, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| MRC | Criteria | Characteristic |
|---|---|---|
| AQCW | ELEMENT MATERIAL | COPPER ALLOY AND PLASTIC, PHENOLIC LAMINATE |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.125 INCHES NOMINAL |
| ABDS | MOUNTING PROVISION QUANTITY | 4 |
| CQTM | TERMINAL LOCATION | TOP |
| ABHP | OVERALL LENGTH | 3.250 INCHES NOMINAL |
| CRCT | CURRENT RATING AND TYPE | 2.0 AMPERES NOMINAL DC |
| SR-5 | THE MANUFACTURERS DATA | |
| APPN | ACCURACY IN PERCENT | NOT RATED |
| ABKW | OVERALL HEIGHT | 0.937 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 1.625 INCHES NOMINAL |
| ALBY | USAGE DESIGN | EXTERNAL |
| CRCM | VOLTAGE DROP IN MILLIVOLTS | 100.0 NOMINAL |
| AXGY | MOUNTING METHOD | UNTHREADED HOLE |
| SR-5 | MANUFACTURERS CODE | 25497 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.375 INCHES NOMINAL |
| SR-5 | DESIGN CONTROL REFERENCE | PR0002-A |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 BINDING POST |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.187 INCHES NOMINAL |
| End Use : 21160 | Measuring, testing, control instruments |
|---|---|
| Schedule B : 9030908030 (NAICS 334515) | Parts and accessories of articles of schedule b subheading 9030.39 |
| SITC : 87479 | Parts and accessories for instruments and apparatus (except meters) measuring etc. Electrical quanities and devices measuring etc. Ionized radiations |
| ADPE | Represents items with no adp components |
|---|---|
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | C |
|---|---|
| Classification Control | U |
| MGMT_CTL | S-09--- |
| Quantity per pack | 1 |
| Repariability | If condemned or economically unserviceable, dispose by theoperator/crew |
| Shelf Life | N/A |
| SOS | Znc |
| Unit of Measure | Ea |