Are you looking quote for part IM74PDR27C? The Joint Electronics Type Designation System-manufactured component (CAGE Code: 80058) is documented under NSN 6665-00-392-7461 as Radiacmeter. For the fastest quote, please complete our RFQ form with details about IM74PDR27C. We guarantee a response within 15 minutes.
ASAP Components provides the verified IM74PDR27C, classified under INC 07833, FSG 66 Instruments and Laboratory Equipment, FSC 6665 Hazard Detecting Instruments And Apparatus, NIIN 00-392-7461, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.
| MRC | Criteria | Characteristic |
|---|---|---|
| ADTY | CASE SURFACE TREATMENT | ENAMEL, GRAY |
| ABMK | OVERALL WIDTH | 5.875 INCHES NOMINAL |
| APPN | ACCURACY IN PERCENT | -2.0 TO 2.0 ALL RANGES |
| AGAV | III END ITEM IDENTIFICATION | TYPE NO. AN/PDR-27C |
| AKWB | III JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM TYPE NUMBER | TYPE NO. IM-74/PDR-27C |
| APPJ | RADIATION RANGE PER HOUR | 0.0 TO 500.0 MILLIROENTGENS |
| APPP | INPUT SENSITIVITY VOLTAGE RATING | NOT RATED |
| APPQ | ENERGY DEPENDENCE RATING | NOT RATED |
| SR-1 | DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | IM74PDR27C |
| AFJU | CARRYING CASE | PROVIDED |
| SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MILR15213 |
| ABHP | OVERALL LENGTH | 12.500 INCHES NOMINAL |
| ALSF | INTERNAL BATTERY ACCOMMODATION | INCLUDED |
| ADTV | CASE MATERIAL | ALUMINUM |
| AMRX | DETECTING ELEMENT TYPE | GEIGER TUBE |
| SR-1 | MANUFACTURERS CODE | 81349 |
| AKWA | III JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM NAME | RADIACMETER |
| AMRM | RADIATION TYPE AND FUNCTION | BETA RAYS MEASURES GAMMA RAYS MEASURES |
| APCB | PORTABILITY | PORTABLE |
| SR-1 | SPEC/STD CONTROLLING DATA | |
| AMKD | INDICATOR TYPE | METER |
| ABKW | OVERALL HEIGHT | 8.000 INCHES NOMINAL |
| End Use : 21600 | Laboratory testing instruments |
|---|---|
| Schedule B : 9022298000 (NAICS 334517) | Apparatus based on the use of alpha, beta or gamma radiations for other use, nesoi |
| SITC : 77422 | Apparatus based on the use of alpha, beta or gamma radiations, whether or not for medical, surgical, dental or veterinary uses, etc. |
| CRITL | The item does not have a critical feature such as tolerance, fit restrictions or application. nuclear hardness properties have not been determined (not valid for input). |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | Z |
|---|---|
| Classification Control | 7 |
| MGMT_CTL | G21tnn- |
| Quantity per pack | 1 |
| Repariability | When repair is beyond lower level maintenance capability, evacuate the item to depot. disposal is not authorized below wholesale level. |
| Shelf Life | N/A |
| SOS | B16 |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LCL: | W - Rating variable |
| LTL: | W - Rating variable |
| NMFC: | 061700 - Elec appliances/instruments noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 658 - Electrical appliances, small |