Are you looking quote for part 20-200? The Joint Electronics Type Designation System-manufactured component (CAGE Code: 80058) is documented under NSN 6625-00-752-8678 as Generator Signal. For the fastest quote, please complete our RFQ form with details about 20-200. We guarantee a response within 15 minutes.
ASAP Components provides the verified 20-200, classified under INC 03901, FSG 66 Instruments and Laboratory Equipment, FSC 6625 Electrical And Electronic Properties Measuring And Testing Instruments, NIIN 00-752-8678, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.
| MRC | Criteria | Characteristic |
|---|---|---|
| ABMK | OVERALL WIDTH | 19.000 INCHES NOMINAL |
| BHGC | SIGNAL OUTPUT CONSTANCY | PORM 1 DB MAX VARIATION |
| ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
| ABKW | OVERALL HEIGHT | 7.000 INCHES NOMINAL |
| AAXX | MOUNTING TYPE | RACK |
| FAAZ | PHASE | SINGLE |
| ADTY | CASE SURFACE TREATMENT | ENAMELED |
| BHFY | CRYSTAL CONTROLLED FEATURE | NOT PROVIDED |
| BHGB | MAXIMUM SIGNAL OUTPUT | 10 V |
| ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
| ABHP | OVERALL LENGTH | 10.500 INCHES NOMINAL |
| BDHW | CALIBRATION ACCURACY RATING | PORM 2 PCT ACCURACY OF CALIBRATION |
| ADTV | CASE MATERIAL | METAL |
| AMSE | VOLTAGE RATING | 100.0 VOLTS MINIMUM AND 130.0 VOLTS MAXIMUM |
| ZZZV | III FSC APPLICATION DATA | TESTER,CRYSTAL |
| AKWA | JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM NAME | GENERATOR,SIGNAL |
| AFGQ | FREQUENCY RANGE RATING | 0.020 TO 20.000 KILOHERTZ |
| AKWB | JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM TYPE NUMBER | TYPE NO. TS-3128/FSM-1 |
| ACDC | CURRENT TYPE | AC |
| AMNE | OUTPUT IMPEDANCE RATING | 1.0 KILOHMS NOMINAL |
| ANLC | FREQUENCY BAND QUANTITY | 4 |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8543200000 (NAICS 334515) | Signal generators |
| SITC : 77878 | Electrical machines and apparatus, having individual functions, n.E.S. (other than particle accelerators) |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LCL: | M - 85.0 |
| LTL: | W - Rating variable |
| NMFC: | 061700 - Elec appliances/instruments noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 658 - Electrical appliances, small |