Are you looking quote for part CX-1689 U(6FT4IN? The Joint Electronics Type Designation System-manufactured component (CAGE Code: 80058) is documented under NSN 5995-00-283-8510 as Cable Assembly Powe. For the fastest quote, please complete our RFQ form with details about CX-1689 U(6FT4IN. We guarantee a response within 15 minutes.
ASAP Components provides the verified CX-1689 U(6FT4IN, classified under INC 00485, FSG 59 Electrical and Electronic Equipment Components, FSC 5995 Cable Cord Wire Assembly Communications Equipment, NIIN 00-283-8510, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5995-00-283-8510 Item PartTypeName: CABLE ASSEMBLY,POWER,ELECTRICAL | 5995 | 002838510 | N | |||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| A | ||||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 47891 | 2 | 9 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
| AAJU | OVERALL LENGTH | 6.396 FEET |
| AMQN | CONDUCTOR QUANTITY | 19 |
| BLNZ | STRAND QUANTITY PER CONDUCTOR | 7 ALL CONDUCTORS |
| CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
| CXDC | ROUND CONDUCTOR SIZE | 18 AWG ALL CONDUCTORS |
| CXDG | STRAND AWG SIZE PER CONDUCTOR | 26 ALL CONDUCTORS |
| CXFK | VOLTAGE RATING | 600.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS |
| CXGG | TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | 17986 1ST END ALL CONDUCTORS |
| CXGG | TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | 18832 2ND END ALL CONDUCTORS |
| CXGN | TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 31746 1ST END ALL CONDUCTORS |
| CXGN | TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 31746 2ND END ALL CONDUCTORS |
| MATT | MATERIAL | RUBBER SYNTHETIC 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
| End Use : 21400 | Telecommunications equipment |
|---|---|
| Schedule B : 9030400000 (NAICS 334515) | Other instruments and apparatus, specially designed for telecommunications (for examle, cross-talk meters, gain measuring instruments etc) |
| SITC : 87477 | Instruments and apparatus, n.E.S., designed for telecommunications (cross-talk meters, gain measuring instruments, distortion factor meters, etc.) |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials. |
| PMIC | A - Item does not contain precious metal. |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | P - 77.5 |
| NMFC: | 061130 - Cable assembly |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 743 - Electrical cable |