Are you looking quote for part MM1R-D3-AC07D-NU-5-2? The Heinemann Electric Co Inc-manufactured component (CAGE Code: L3330) is documented under NSN 5925-01-377-3400 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about MM1R-D3-AC07D-NU-5-2. We guarantee a response within 15 minutes.
ASAP Components provides the verified MM1R-D3-AC07D-NU-5-2, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 01-377-3400, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-377-3400 Item PartTypeName: CIRCUIT BREAKER | 5925 | 013773400 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| MM1R-D3-AC07D-NU-5-2 | 5 | 2 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | Body Style | SINGLE POLE TYPE |
| AKPX | Pole Quantity | 1 |
| AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.062 INCHES NOMINAL |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC SINGLE LOCATION AND 5.0 AMPERES DC SINGLE LOCATION |
| AJWX | Mounting Surface To Terminal End Distance | 2.481 INCHES NOMINAL |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC SINGLE LOCATION AND 5000.0 DC SINGLE LOCATION |
| CTTC | Thread Tolerance Class | EXTERNAL |
| FREQ | Frequency In Hertz | 60.0 SINGLE LOCATION |
| CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| CPRL | Trip Release Characteristic | INSTANTANEOUS SINGLE LOCATION |
| AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
| CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC SINGLE LOCATION |
| AJEC | Boss Height | 0.140 INCHES NOMINAL |
| THSD | Thread Series Designator | UNC |
| ADAT | Body Width | 0.750 INCHES NOMINAL |
| CPRQ | Reset Method | MANUAL |
| CPRW | Actuator Function | RESET |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
| CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| CQJX | Nominal Thread Size | 0.138 INCHES |
| ADTV | Case Material | PLASTIC |
| ADAQ | Body Length | 2.500 INCHES NOMINAL |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.938 INCHES NOMINAL |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SINGLE LOCATION AND 65.0 DC SINGLE LOCATION |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 135.0 SINGLE LOCATION |
| CPRX | Actuator Position Designation | AT POLE ONE |
| AGAV | End Item Identification | 24VDC PANEL P/N 2009-002-03 ONBOARD 47 FT MLB CLASS COAST GUARD VESSELS |
| CMLP | Thread Quantity Per Inch | 32 |
| MRC | Decoded Requirement | Clear Text Reply |
| TTQY | Terminal Type And Quantity | 2 THREADED STUD |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8536200040 (NAICS 335313) | Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi |
| SITC : 77252 | Automatic circuit breakers for a voltage not exceeding 1, 000 volts |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | C |
|---|---|
| Classification Control | U |
| MGMT_CTL | A-09--- |
| Quantity per pack | 1 |
| Repariability | If condemned or economically unserviceable, dispose by theoperator/crew |
| Shelf Life | N/A |
| SOS | Znc |
| Unit of Measure | Ea |