Quote for 160801 General Signal Corp Part with NSN 5950-00-944-2861

Part Number:  160801
Manufacturer:  general signal corp
NIIN:  9442861
Item Name :  transformer power
CAGE Code:  72419
INC Code:  32496
Country:  USA
NCB Code:  00
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  02-03-2026

Are you looking quote for part 160801? The General Signal Corp-manufactured component (CAGE Code: 72419) is documented under NSN 5950-00-944-2861 as Transformer Power. For the fastest quote, please complete our RFQ form with details about 160801. We guarantee a response within 15 minutes.

ASAP Components provides the verified 160801, classified under INC 32496, FSG 59 Electrical and Electronic Equipment Components, FSC 5950 Coils and Transformers, NIIN 00-944-2861, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for 160801

“*” Required Fields Are Compulsory

NSN Information for Part Number 160801 with NSN 5950-00-944-2861, 5950009442861

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5950-00-944-2861

Item PartTypeName:

TRANSFORMER,POWER

59500094428610P
CIICHCCESDPMICCriticalityENAC
U U
Part NumberISCRNVCRNCCHCCMSDSSADC
160801625

Characteristics Data of NSN 5950-00-944-2861, 5950009442861

MRCCriteriaCharacteristic
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.110 INCHES MINIMUM AND 3.130 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.110 INCHES MINIMUM AND 2.130 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZBFREQUENCY RATING380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
ACZCINPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO SINGLE PHASE SINGLE COMPONENT
ACZDTRANSFORMER WINDING CONNECTION TYPEWYE-WYE
ACZFMAXIMUM TRANSFORMER POWER RATING28.1 VOLT-AMPERE SINGLE COMPONENT
ADAQBODY LENGTH3.880 INCHES MAXIMUM
ADATBODY WIDTH2.620 INCHES MAXIMUM
ADAUBODY HEIGHT1.750 INCHES MAXIMUM
AKNAINCLOSURE TYPEFULLY INCLOSED
AKPVMOUNTING FACILITY QUANTITY4 SINGLE GROUP
AXGYMOUNTING METHODTHREADED HOLE SINGLE GROUP
BPLCWINDING FUNCTION AND QUANTITY1 PRIMARY AND 6 SECONDARY SINGLE COMPONENT
CQJXNOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
CRBZWINDING OPERATING CURRENT17.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
CRBZWINDING OPERATING CURRENT23.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY
CRBZWINDING OPERATING CURRENT25.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
CRBZWINDING OPERATING CURRENT600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
CRMJWINDING POWER RATING0.75 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
CRMJWINDING POWER RATING15.6 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
CRMJWINDING POWER RATING2.25 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
CRMJWINDING POWER RATING2.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
CWJSWINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
CWJSWINDING OPERATING VOLTAGE25.00 AC VOLTS NOMINAL AND 75.00 AC VOLTS NOMINAL AND 100.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
CWJSWINDING OPERATING VOLTAGE26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
CWJSWINDING OPERATING VOLTAGE30.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
CWJSWINDING OPERATING VOLTAGE36.00 AC VOLTS NOMINAL AND 144.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
FEATSPECIAL FEATURESONE PRIMARY WINDING; SIX SECONDARY WINDINGS WITH 3RD AND 6TH WINDINGS CENTER TAPPED AND 1ST AND 4TH WINDINGS MULTIPLE TAPPED W/CENTER TAP
THSDTHREAD SERIES DESIGNATORUNC SINGLE GROUP
TTQYTERMINAL TYPE AND QUANTITY24 TURRET

Schedule B & Trade

End Use : 20000 Generators, accessories
Schedule B : 8504314035 (NAICS 334416) Transformers, having a power handling capacity less than 40 va, nesoi
SITC : 77119 Electric transformers, n.E.S.

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC U - Precious metal content is unknown

NSN Management Codes

AAC Z
Classification Control U
MGMT_CTL Sf9eh-n
Quantity per pack 1
Repariability
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: W - Rating variable
NMFC: 063420 - Transformers, noi, or transformer par
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 595 - Transformer, (machinery and parts),(less than 35 feet)

ASAP Semiconductor’s Certifications And Memberships



bottom to top