Quote for 53-119MG3-10-416VAC1-400CY Eaton Corporation Part with NSN 5925-00-655-3890

Part Number:  53-119MG3-10-416VAC1-400CY
Alternate P/N:  53119MG310416VAC1400CY
Manufacturer:  eaton corporation
NIIN:  6553890
Item Name :  circuit breaker
CAGE Code:  74193
INC Code:  00136
Country:  USA
NCB Code:  00
FSG:  59 Electrical and Electronic Equipment Components
Last Updated:  02-05-2026

Are you looking quote for part 53-119MG3-10-416VAC1-400CY? The Eaton Corporation-manufactured component (CAGE Code: 74193) is documented under NSN 5925-00-655-3890 as Circuit Breaker. For the fastest quote, please complete our RFQ form with details about 53-119MG3-10-416VAC1-400CY. We guarantee a response within 15 minutes.

ASAP Components provides the verified 53-119MG3-10-416VAC1-400CY, classified under INC 00136, FSG 59 Electrical and Electronic Equipment Components, FSC 5925 Circuit Breakers, NIIN 00-655-3890, and NCB 00. Submit your requirements today to receive immediate pricing and availability information.

Please fill out below form for 53-119MG3-10-416VAC1-400CY

“*” Required Fields Are Compulsory

NSN Information for Part Number 53-119MG3-10-416VAC1-400CY with NSN 5925-00-655-3890, 5925006553890

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-00-655-3890

Item PartTypeName:

CIRCUIT BREAKER

59250065538900P
CIICHCCESDPMICCriticalityENAC
U U
Part NumberISCRNVCRNCCHCCMSDSSADC
3XAM1516MG3-10-416VAC11295

Characteristics Data of NSN 5925-00-655-3890, 5925006553890

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ADAQBODY LENGTH3.709 INCHES MINIMUM AND 3.729 INCHES MAXIMUM
ADATBODY WIDTH3.042 INCHES MINIMUM AND 3.062 INCHES MAXIMUM
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.053 INCHES MINIMUM AND 3.073 INCHES MAXIMUM
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.021 INCHES MINIMUM AND 1.041 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.021 INCHES MINIMUM AND 1.041 INCHES MAXIMUM
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHT0.146 INCHES MINIMUM AND 0.166 INCHES MAXIMUM
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE3.239 INCHES NOMINAL
AKPXPOLE QUANTITY3
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE10.0 AMPERES AC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS416.0 AC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1500.0 AC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY3 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE,TWO,AND THREE LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT40.000 MINIMUM AT 200 PCT AND 105.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF AND FUNGUS PROOF
CWJKCASE MATERIALPLASTIC
FREQFREQUENCY IN HERTZ400.0 ALL LOCATIONS
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY6 THREADED STUD

Schedule B & Trade

End Use : 20005 Electric apparatus
Schedule B : 8536200040 (NAICS 335313) Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi
SITC : 77252 Automatic circuit breakers for a voltage not exceeding 1, 000 volts

Identification

CRITL The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
PMIC U - Precious metal content is unknown

NSN Management Codes

AAC J
Classification Control U
MGMT_CTL Q2200x-
Quantity per pack 1
Repariability This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item.
Shelf Life N/A
SOS Sms
Unit of Measure Ea

Freight Information

ACC: H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ADC: A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
LTL: P - 77.5
NMFC: 061300 - Circuit breaker/switch noi
SHC: 9 - Other or no special handling required (sh)
TCC: Z - No special type of cargo code applicable
WCC: 658 - Electrical appliances, small

ASAP Semiconductor’s Certifications And Memberships



bottom to top