Are you looking quote for part 611GCEM2? The Custom Control Sensors Inc-manufactured component (CAGE Code: 09049) is documented under NSN 5930-01-147-3875 as Switch Pressure. For the fastest quote, please complete our RFQ form with details about 611GCEM2. We guarantee a response within 15 minutes.
ASAP Components provides the verified 611GCEM2, classified under INC 00206, FSG 59 Electrical and Electronic Equipment Components, FSC 5930 Switches, NIIN 01-147-3875, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5930-01-147-3875 Item PartTypeName: SWITCH,PRESSURE | 5930 | 011473875 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 611GCEM2 | 5 | 1 | C | A |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
| ABHP | OVERALL LENGTH | 4.000 INCHES MAXIMUM |
| ABPM | BODY DIAMETER | 1.440 INCHES NOMINAL |
| ADAV | OVERALL DIAMETER | 1.870 INCHES NOMINAL |
| AGAV | END ITEM IDENTIFICATION | 98072-VA-101 |
| AJZC | PRESSURE SWITCH TYPE | GAGE |
| AXGY | MOUNTING METHOD | INPUT PORT |
| CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE AND ELECTRICAL ACCESS PORT |
| CMLP | THREAD QUANTITY PER INCH | 18 SINGLE PRESSURE CONNECTION |
| CQGB | CONTACT ACTION STIMULUS | INCREASE |
| CQJB | PROOF PRESSURE | 1000.00 POUNDS PER SQUARE INCH |
| CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE PRESSURE CONNECTION |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
| CSCF | TERMINAL TYPE | WIRE LEAD |
| CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD AND 3.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD AND 250.0 MILLIAMPERES INDUCTIVE LOAD THIRD VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD AND 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| CTYM | CONTACT ADJUSTMENT RANGE | 13.00 TO 80.00 ACTUATION POINT POUNDS PER SQUARE INCH AND 11.60 TO 72.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
| CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT HEX NUT AND EXTERNAL ACTUATION POINT HEX NUT |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 125.0 DC AT SEA LEVEL THIRD VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
| CTZL | PRESSURE CONNECTOR TYPE | FLARED,THREADED EXTERNAL SINGLE CONNECTION |
| FREQ | FREQUENCY IN HERTZ | 50.0 AND 60.0 FIRST VOLTAGE |
| MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| THSD | THREAD SERIES DESIGNATOR | PTF-SAE SHORT SINGLE PRESSURE CONNECTION |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8536509065 (NAICS 335931) | Switches, for a voltage not exceeding 1000 volts, nesoi |
| SITC : 77255 | Switches for electrical apparatus, n.E.S., for voltages not exceeding 1, 000 volts |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | D |
|---|---|
| Classification Control | U |
| MGMT_CTL | 3b----- |
| Quantity per pack | 1 |
| Repariability | When repair is beyond lower level maintenance capability, evacuate the item to depot. disposal is not authorized below wholesale level. |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | P - 77.5 |
| NMFC: | 061300 - Circuit breaker/switch noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 658 - Electrical appliances, small |