Are you looking quote for part F280-1440-1? The Carleton Technologies Inc-manufactured component (CAGE Code: 04577) is documented under NSN 6685-01-383-2747 as Indicator Temperatu. For the fastest quote, please complete our RFQ form with details about F280-1440-1. We guarantee a response within 15 minutes.
ASAP Components provides the verified F280-1440-1, classified under INC 03395, FSG 66 Instruments and Laboratory Equipment, FSC 6685 Pressure Temperature And Humidity Measuring And Controlling Instruments, NIIN 01-383-2747, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| MRC | Criteria | Characteristic |
|---|---|---|
| AMNL | PRESENTATION TYPE | DIGITAL DISPLAY |
| ABGL | WIDTH | 6.000 INCHES NOMINAL |
| ASKX | ELECTRICAL CONNECTION QUANTITY | 1 |
| FEAT | SPECIAL FEATURES | INCLUDES THERMOCOUPLE PROBE ASSY;PURGE HOSE ASSY,AND COMPRESSION FITTING FOR THERMOCOUPLE DIA.,ITEM IN CONTACT WITH LOX MUST BE OXYGEN CLEANED,ALL ITEM INCLUDED IN CARRYING CASE,USE FOR MONITORING LOX PUTGE TEMPERATURES |
| HGTH | HEIGHT | 2.500 INCHES NOMINAL |
| ACDC | CURRENT TYPE | DC |
| ABRY | LENGTH | 10.000 INCHES NOMINAL |
| BFQN | DISPLAY TYPE | LIQUID CRYSTAL |
| CWJK | CASE MATERIAL | ALUMINUM |
| End Use : 21610 | Medicinal equipment |
|---|---|
| Schedule B : 9025900000 (NAICS 334519) | Parts and accessories for hydrometers and similar floating instruments, therometers, pyrometers, barometers, hygrometers and psychrometers |
| SITC : 87456 | Parts and accessories for hydrometers and similar floating instruments, thermometers, pyrometers, barometers, hygrometers and psychrometers |
| ADPE | Represents items with no adp components |
|---|---|
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | J |
|---|---|
| Classification Control | U |
| MGMT_CTL | --ybo-e |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Fhz |
| Unit of Measure | Ea |
| ACC: | E - Engineer supplies, other than those listed under code b. |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | F - 150.0 |
| NMFC: | 058240 - Recording devices gauges/meters noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 652 - Instruments, scientific |