Are you looking quote for part 1855012? The C Q Construction Corporation-manufactured component (CAGE Code: 0CRU0) is documented under NSN 5920-01-371-1474 as Absorber Overvoltag. For the fastest quote, please complete our RFQ form with details about 1855012. We guarantee a response within 15 minutes.
ASAP Components provides the verified 1855012, classified under INC 21899, FSG 59 Electrical and Electronic Equipment Components, FSC 5920 Fuses Arresters Absorbers and Protector, NIIN 01-371-1474, and NCB 01. Submit your requirements today to receive immediate pricing and availability information.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5920-01-371-1474 Item PartTypeName: ABSORBER,OVERVOLTAGE | 5920 | 013711474 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 1855012 | 5 | 2 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARA | TERMINAL QUANTITY | 6 |
| AARB | TERMINAL TYPE | SCREW |
| ABHP | OVERALL LENGTH | 4.950 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 2.800 INCHES NOMINAL |
| ALGC | MOUNTING CONFIGURATION | FOUR 0.185 IN. DIA THRU HOLES ON 4.200 IN. X 2.250 IN. CENTERS |
| ALPY | POLARIZATION FEATURE | INCLUDED |
| AMPS | CURRENT RATING IN AMPS | 7.500 |
| AQAY | CURRENT INTERRUPTING CAPACITY | 12000.0 KILOAMPERES MAXIMUM |
| AQCS | HERMETIC PROTECTION | PROVIDED |
| AQCT | SHUNT CAPACITOR | NOT INCLUDED |
| ELEC | VOLTAGE IN VOLTS | 120.0 |
| ACDC | CURRENT TYPE | AC |
| ADJH | MOUNTING METHOD | HOLES |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8536908010 (NAICS 335313) | Electrical distribution ducts, for a voltage not exceeding 1, 000 v |
| SITC : 77259 | Electrical apparatus for switching or protecting electrical circuits or making connections to or in electrical circuits, n.E.S., not exceeding 1, 000 v |
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | A - Item does not contain precious metal. |
| AAC | J |
|---|---|
| Classification Control | U |
| MGMT_CTL | Sf9eh-n |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | P - 77.5 |
| NMFC: | 062380 - Lightning arresters/parts noi |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 72D - Communications/electronics, other than sigint/ew or comsec repair parts and components |